-
1 барабан для бумаги
( самопишущего прибора) paper drumАнгло-русский словарь технических терминов > барабан для бумаги
-
2 rated current
- установленный ток
- расчётный ток
- паспортный ток
- нормируемый ток
- номинальный ток (св.)
- номинальный ток
номинальный ток
Ток, указанный изготовителем на приборе
Примечание.
Если ток для прибора не указан, то номинальный ток равен:- для нагревательных приборов – току, рассчитанному по номинальной потребляемой мощности и номинальному напряжению;
- для электромеханических и комбинированных приборов – току, измеренному в период работы прибора в условиях нормальной работы при номинальном напряжении.
EN
rated current
current assigned to the appliance by the manufacturer
NOTE - If no current is assigned to the appliance, the rated current is
– for heating appliances, the current calculated from the rated power input and the rated voltage;
– for motor-operated appliances and combined appliances, the current measured when the appliance is supplied at rated voltage and operated under normal operation.
[IEC 60335-1, ed. 4.0 (2001-05)]FR
courant assigné
courant attribué à l'appareil par le fabricant
NOTE - Si aucun courant n'est attribué à l'appareil, le courant assigné est
– pour les appareils chauffants, le courant calculé à partir de la puissance assignée et de la tension assignée;
– pour les appareils à moteur et les appareils combinés, le courant mesuré lorsque l'appareil est alimenté sous la tension assignée et mis en fonctionnement dans les conditions de fonctionnement normal.
[IEC 60335-1, ed. 4.0 (2001-05)]2
номинальный ток
значение тока, являющееся исходным при установлении требований настоящего стандарта к счетчику.
[ ГОСТ 6570-96]Тематики
EN
FR
номинальный ток (св.)
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
EN
нормируемый ток
Максимальный ток, заявленный изготовителем, на который рассчитан патрон.
[ ГОСТ Р МЭК 60838-1-2008]Тематики
- лампы, светильники, приборы и комплексы световые
EN
паспортный ток
-
[IEV number 314-07-02]EN
rated current
value of current in accordance with which the relevant performance of a transformer operated meter is fixed
[IEV number 314-07-02]FR
courant assigné
valeur du courant en fonction de laquelle certaines des caractéristiques d’un compteur alimenté par transformateur(s) sont fixées
[IEV number 314-07-02]Тематики
- измерение электр. величин в целом
EN
DE
FR
расчётный ток
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
3.18 номинальный ток (rated current): Ток, установленный для выключателя изготовителем.
Источник: ГОСТ Р 51324.1-2005: Выключатели для бытовых и аналогичных стационарных электрических установок. Часть 1. Общие требования и методы испытаний оригинал документа
3.2.6 номинальный ток (rated current): Ток, указанный на машине изготовителем. Номинальный ток, не указанный на машине, определяют измерением при работе машины при номинальном напряжении и нормальной нагрузке.
Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.26 номинальный ток (rated current): Ток, установленный изготовителем соединителей, который указан в стандартах или технических условиях.
Источник: ГОСТ Р 51322.1-2011: Соединители электрические штепсельные бытового и аналогичного назначения. Часть 1. Общие требования и методы испытаний оригинал документа
2.3 нормируемый ток (rated current): Максимальный ток, заявленный изготовителем, на который рассчитан патрон.
Источник: ГОСТ Р МЭК 60838-1-2008: Патроны различные для ламп. Часть 1. Общие требования и методы испытаний оригинал документа
1.2.1.3 номинальный ток (rated current): Указанный изготовителем ток, потребляемый оборудованием.
Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
1.2.1.3 номинальный ток (rated current): Указанный изготовителем ток, потребляемый оборудованием.
Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
3.13 установленный ток (rated current); IN: Ток измерительной аппаратуры при установленных условиях.
Источник: ГОСТ Р 54127-1-2010: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
3.33 номинальный ток (rated current): Ток, определенный для машины изготовителем. Если данный параметр для машины не установлен, то под номинальным током для целей настоящего стандарта понимают ток, измеренный при работе машины при нормальной нагрузке.
Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.2.6 номинальный ток (rated current): Ток, указанный на машине изготовителем. Номинальный ток, не указанный на машине, определяют измерением при работе машины при номинальном напряжении и нормальной нагрузке.
3.15 номинальный ток (rated current), IH (IN): Ток, пропускаемый реактором при номинальных мощности и напряжении.
3.16
Источник: ГОСТ Р 54801-2011: Трансформаторы тяговые и реакторы железнодорожного подвижного состава. Основные параметры и методы испытаний оригинал документа
3.102 номинальный ток (rated current): Ток, указанный изготовителем входных(ого) устройств(а), а при подключении более одного входного устройства - ток, указанный изготовителем и представляющий собой арифметическую сумму токов всех входных устройств, предназначенных работать одновременно.
Источник: ГОСТ Р 50827.5-2009: Коробки и корпусы для электрических аппаратов, устанавливаемые в стационарные электрические установки бытового и аналогичного назначения. Часть 24. Специальные требования к коробкам и корпусам, предназначенным для установки защитных и аналогичных аппаратов с большой рассеиваемой мощностью оригинал документа
3.1.6 номинальный ток (rated current): Ток, указанный изготовителем на приборе.
Примечание - Если ток для прибора не указан, то номинальный ток равен:
- для нагревательных приборов - току, рассчитанному по номинальной потребляемой мощности и номинальному напряжению;
- для электромеханических и комбинированных приборов - току, измеренному в период работы прибора в условиях нормальной работы при номинальном напряжении.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
3.2.6 номинальный ток (rated current): Значение входного или выходного тока оборудования, указанное производителем.
Источник: ГОСТ Р 55061-2012: Совместимость технических средств электромагнитная. Статические системы переключения. Часть 2. Требования и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated current
-
3 rated voltage
- регламентированное напряжение
- расчетное напряжение
- нормируемое напряжение
- номинальное напряжение конденсатора
- номинальное напряжение (во взрывозащите)
- номинальное напряжение
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
номинальное напряжение
Значение напряжения, на которое рассчитаны рабочие и эксплуатационные характеристики распределенных электронагревателей.
[ ГОСТ Р МЭК 60050-426-2006]
Тематики
EN
номинальное напряжение конденсатора
Максимальное напряжение, при котором конденсатор может работать в течение минимальной наработки в условиях, указанных в нормативно-технической документации
[ ГОСТ 21415-75]
номинальное напряжение конденсатора
Действующее значение синусоидального переменного напряжения при номинальной частоте, на которое рассчитан конденсатор. Номинальное напряжение многофазного конденсатора - значение напряжения между выводами.
[ ГОСТ 1282-88]Тематики
- конденсаторы для повыш. коэф. мощности
- конденсаторы для электронной аппаратуры
EN
DE
FR
нормируемое напряжение
Питающее напряжение или напряжение, на которое светильник рассчитан изготовителем.
[ ГОСТ Р МЭК 60598-1-2014]Тематики
- лампы, светильники, приборы и комплексы световые
EN
расчетное напряжение
номинальное напряжение
нормальное эксплуатационное напряжение
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
Синонимы
EN
расчётное напряжение
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]Тематики
- электротехника, основные понятия
EN
3.17 номинальное напряжение (rated voltage): Напряжение, установленное для выключателя изготовителем.
Источник: ГОСТ Р 51324.1-2005: Выключатели для бытовых и аналогичных стационарных электрических установок. Часть 1. Общие требования и методы испытаний оригинал документа
1.5.10 номинальное напряжение (rated voltage): Номинальное напряжение - это либо эффективное значение рабочего напряжения номинальной частоты, либо рабочее постоянное напряжение, которое можно длительно подавать на выводы конденсатора при любой температуре между нижней и верхней температурами категории. Это означает, что у конденсаторов, на которые распространяется настоящий стандарт, напряжение категории равно номинальному напряжению.
Источник: ГОСТ Р МЭК 60384-14-2004: Конденсаторы постоянной емкости для электронной аппаратуры. Часть 14. Групповые технические условия на конденсаторы постоянной емкости для подавления электромагнитных помех и соединения с питающими магистралями оригинал документа
3.2.1 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем для этой машины, или напряжение между фазами (линейное) - при трехфазном питании.
Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.25 номинальное напряжение (rated voltage): Напряжение, установленное изготовителем соединителей, которое указывается в стандартах или технических условиях.
Источник: ГОСТ Р 51322.1-2011: Соединители электрические штепсельные бытового и аналогичного назначения. Часть 1. Общие требования и методы испытаний оригинал документа
3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжений, маркируемый на лампе.
Источник: ГОСТ Р 53881-2010: Лампы со встроенными пускорегулирующими аппаратами для общего освещения. Требования безопасности оригинал документа
3.23 номинальное напряжение (rated voltage): Значение напряжения, на которое рассчитаны рабочие и эксплуатационные характеристики распределенных электронагревателей.
Источник: ГОСТ Р МЭК 60079-30-1-2009: Взрывоопасные среды. Резистивный распределенный электронагреватель. Часть 30-1. Общие технические требования и методы испытаний оригинал документа
1.5.9 номинальное напряжение (rated voltage): Напряжение или диапазон напряжения, заданное(ый) в соответствии с настоящим стандартом.
Примечание - Если в маркировке на лампе приведен диапазон напряжения, это значит, что возможна эксплуатация ламп при любом значении напряжения в пределах этого диапазона.
Источник: ГОСТ Р 52706-2007: Лампы накаливания вольфрамовые для бытового и аналогичного общего освещения. Эксплуатационные требования оригинал документа
2.1 нормируемое напряжение (rated voltage): Максимальное рабочее напряжение, заявленное изготовителем, на которое рассчитан патрон.
Источник: ГОСТ Р МЭК 60838-1-2008: Патроны различные для ламп. Часть 1. Общие требования и методы испытаний оригинал документа
1.2.1.1. номинальное напряжение (rated voltage): Указанное изготовителем напряжение источника сетевого электропитания (для трехфазного источника электропитания принимают линейное напряжение).
Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
1.2.1.1 номинальное напряжение (rated voltage): Указанное изготовителем напряжение источника сетевого электропитания (для трехфазного источника электропитания принимают линейное напряжение).
Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
3.37 номинальное напряжение (rated voltage): Значение напряжения для заданных условий эксплуатации.
Значение и условия должны быть указаны в соответствующем стандарте или изготовителем, или ответственным поставщиком.
Примечание - Номинальное напряжение выражают в вольтах (В).
Источник: ГОСТ Р 54814-2011: Светодиоды и светодиодные модули для общего освещения. Термины и определения оригинал документа
3.4 номинальное напряжение (rated voltage): Напряжение, указанное для прибора производителем.
Источник: ГОСТ Р МЭК 62301-2011: Приборы бытовые электрические. Измерение потребляемой мощности в режиме ожидания оригинал документа
1.3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжения, заданное(ый) в соответствии с настоящим стандартом.
Примечание - Если в маркировке на лампе приведен диапазон напряжения, это значит, что возможна эксплуатация ламп при любом значении напряжения в пределах этого диапазона.
Источник: ГОСТ Р 52712-2007: Требования безопасности для ламп накаливания. Часть 1. Лампы накаливания вольфрамовые для бытового и аналогичного общего освещения оригинал документа
3.40 номинальное напряжение (rated voltage): Напряжение, установленное для машины изготовителем. При трехфазном питании - напряжение между фазами.
Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.2.1 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем для этой машины, или напряжение между фазами (линейное) - при трехфазном питании.
3.11 номинальное напряжение (rated voltage), UH (UN): Напряжение при номинальной частоте, прикладываемое между линейными выводами обмотки.
Источник: ГОСТ Р 54801-2011: Трансформаторы тяговые и реакторы железнодорожного подвижного состава. Основные параметры и методы испытаний оригинал документа
1.3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжений, маркируемые на лампе.
Источник: ГОСТ Р 53879-2010: Лампы со встроенными пускорегулирующими аппаратами для общего освещения. Эксплуатационные требования оригинал документа
3.2 номинальное напряжение (rated voltage): Напряжение или диапазон напряжений, маркируемый на лампе.
Источник: ГОСТ Р МЭК 62560-2011: Лампы светодиодные со встроенным устройством управления для общего освещения на напряжения свыше 50 В. Требования безопасности оригинал документа
3.103 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем, для конкретного корпуса.
Источник: ГОСТ Р 50827.5-2009: Коробки и корпусы для электрических аппаратов, устанавливаемые в стационарные электрические установки бытового и аналогичного назначения. Часть 24. Специальные требования к коробкам и корпусам, предназначенным для установки защитных и аналогичных аппаратов с большой рассеиваемой мощностью оригинал документа
3.2.1 номинальное напряжение (rated voltage); Ur:Междуфазное напряжение на выводах генератора при номинальных частоте и мощности.
Примечание - Номинальное напряжение генератора для рабочих и эксплуатационных характеристик устанавливает изготовитель.
Источник: ГОСТ Р 53986-2010: Электроагрегаты генераторные переменного тока с приводом от двигателя внутреннего сгорания. Часть 3. Генераторы переменного тока оригинал документа
3.2.1. номинальное напряжение (rated voltage):
Напряжение, для которого сконструирована установка (или ее часть).
Источник: ГОСТ Р МЭК 60519-1-2005: Безопасность электротермического оборудования. Часть 1. Общие требования оригинал документа
3.1.1 номинальное напряжение (rated voltage): Напряжение, установленное изготовителем для прибора.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель и которое служит для определения параметров электрических испытаний.
Источник: ГОСТ Р МЭК 60245-1-2006: Кабели с резиновой изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа
2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель и которое служит для определения параметров электрических испытаний.
Примечание 1 - Номинальное напряжение выражается сочетанием двух значений U0/U, выраженных в вольтах (В):
U0 - среднеквадратическое значение между любой изолированной жилой и «землей» (металлическим покрытием кабеля или окружающей средой);
U - среднеквадратическое значение между любыми двумя фазными жилами многожильного кабеля или системы одножильных кабелей.
В системе переменного тока номинальное напряжение кабеля должно быть не менее номинального напряжения системы, для которой он предназначен.
Это условие относится как к значению U0, так и к значению U.
В системе постоянного тока номинальное напряжение системы должно быть не более полуторного значения номинального напряжения кабеля.
Примечание 2 - Рабочее напряжение системы может постоянно превышать номинальное напряжение такой системы до 10 %. Кабель можно использовать при рабочем напряжении на 10 % выше его номинального напряжения, если последнее по крайней мере равно номинальному напряжению системы.
Источник: ГОСТ Р МЭК 60245-1-2009: Кабели с резиновой изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа
1.2.11 нормируемое напряжение (rated voltage): Питающее напряжение или напряжение, на которое светильник рассчитан изготовителем.
Источник: ГОСТ Р МЭК 60598-1-2011: Светильники. Часть 1. Общие требования и методы испытаний оригинал документа
2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель, служащее для определения параметров электрических испытаний.
Номинальное напряжение выражают сочетанием двух значений - U0/U, выраженных в вольтах:
U0- среднеквадратическое значение между любой изолированной жилой и «землей» (металлическим покрытием кабеля или окружающей средой);
U - среднеквадратическое значение между любыми двумя фазными жилами многожильного кабеля или системы одножильных кабелей.
В системе переменного тока номинальное напряжение кабеля должно быть не менее номинального напряжения системы, для которого он предназначен.
Это требование относится как к значению U0, так и к значению U.
В системе постоянного тока номинальное напряжение системы должно быть не более полуторного значения номинального напряжения кабеля.
Примечание - Рабочее напряжение системы может постоянно превышать номинальное напряжение этой системы до 10 %. Кабель можно использовать при рабочем напряжении, на 10 % превышающем номинальное напряжение, если последнее по крайней мере равно номинальному напряжению системы.
Источник: ГОСТ Р МЭК 60227-1-2009: Кабели с поливинилхлоридной изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа
3.2.4 регламентированное напряжение (rated voltage): Входное или выходное напряжение (напряжение фаза - фаза для трехфазного источника питания), указанное производителем.
Источник: ГОСТ Р 55061-2012: Совместимость технических средств электромагнитная. Статические системы переключения. Часть 2. Требования и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated voltage
-
4 cradle
['kreɪdl]1) Общая лексика: воспитывать с самого раннего детства, истоки, качать в люльке, колыбель, лоток для промывки золотоносного песка, младенчество, положить на рычаг, помещать в считыватель (Используется применительно к индивидуальным датчикам, служащим для фиксации условий окружающей среды (напр., изменений температурного режима, состава атмосферы и т.п.) на протяжении транспортировки груза), промывать (золотой песок), рама, рычаг (телефона), спусковые салазки, убаюкать, убаюкивать, хвататься, держаться, начало, подставка для подзарядки (мобильных телефонов, машинок для стрижки волос и проч.), бережно держать2) Геология: вашгерд американского типа, лоток для промывки золота, роккер3) Морской термин: шлюпочный кильблок, стеллаж (конструкция, на которую устанавливается спасательный плот)4) Медицина: подвешенная секция (для лечения перелома кости), поддержка, шина, ложе6) Военный термин: люлька (орудия), люлька (механизм)7) Техника: лотковая опора (трубопровода), лоток (для промывки золота), направляющая; опора, опора, опорная рама, поддерживать, подушка, стакан (для подзарядки аккумуляторных батарей)8) Сельское хозяйство: коник, кружало, морской плот рамной конструкции, накопитель, платформа с двумя кониками, подготовленная площадка9) Строительство: клетка, седловая опора (трубопровода), тележка (эллинга или слипа)10) Железнодорожный термин: седлообразный, подушка (щита)12) Архитектура: люлька (в том числе и для подъема людей или грузов)13) Артиллерия: вертлюг (пулемёта)14) Горное дело: вашгерд, крюк, опорная рама (напр. лебёдки), подвесной полок (в стволе), промыть, салазки (колонкового бурильного молотка), сруб, люлька (строительная)15) Лесоводство: (лесо) коник, (лесо) кружало, (лесо) накопитель, (лесо) платформа с двумя кониками, (лесо) подготовленная площадка (для валки деревьев), (лесо) морской плот рамной конструкции (для леса)19) Электроника: база (напр., сканера штрих-кодов)20) Нефть: подвесная платформа (для ремонтных работ), рама фундамента (для машины), салазки (для крепления перфоратора на распорной колонке)21) Космонавтика: балансир, опорная подушка, основание для прибора, платформа, подвесная клеть, подвесные подмостки, рама связки ракетных ускорителей, связка ракетных ускорителей, ложемент (генетрона)22) Машиностроение: лафета, опорные козлы, тачка23) Воздухоплавание: ложемент24) Экология: захват для мусорных бачков25) Бурение: гнездо, лотковая опора для трубопровода, подвесная платформа для производства ремонтных работ, рама фундамента для машины26) Нефтегазовая техника подвесная платформа для ремонтных работ, рама фундамента под насос27) Нефтепромысловый: фундаментная рама28) Автоматика: (зуборезного станка) люлька29) Медицинская техника: дека (В МРТ - Часть стола для исследования пациента, перемещающая пациента в магнит. (из инструкции к МРТ))30) Макаров: воспитывать с младенчества, воспитывать с раннего детства, лесонакопитель, класть на рычаг (телефонную трубку)31) Табуированная лексика: качать32) Аккумуляторы: крэдл33) Яхтенный спорт: кильблок (подставка для перевозки/хранения под лодки и катера) -
5 rated pressure
индикаторное давление
номинальное давление
—
[ http://slovarionline.ru/anglo_russkiy_slovar_neftegazovoy_promyishlennosti/]Тематики
Синонимы
EN
номинальное давление компрессора
номинальное давление
Расчетное значение давления.
[ ГОСТ 28567-90]Тематики
Синонимы
EN
DE
3.107 номинальное давление (rated pressure): Давление воды, установленное для прибора изготовителем.
А - нагревательный элемент; B - бак; С - выходная труба; D - труба расширения; Е - шаровой клапан; F - уровень воды; G - резервуар; Н - вентиляционная труба
Типы водонагревателей:
а - закрытый водонагреватель; b - водонагреватель со свободным сливом; с - водонагреватель, питаемый от отдельного резервуара; d - водонагреватель со встроенным резервуаром; е - водонагреватель низкого давления
Рисунок 101 - Примеры аккумуляционных водонагревателей
Источник: ГОСТ Р 52161.2.21-2006: Безопасность бытовых и аналогичных электрических приборов. Часть 2.21. Частные требования для аккумуляционных водонагревателей оригинал документа
99. Номинальное давление компрессора
Номинальное давление
D. Nenndruck
E. Rated pressure
Расчетное значение давления
Источник: ГОСТ 28567-90: Компрессоры. Термины и определения оригинал документа
3.105 номинальное давление (rated pressure): Давление воды, указанное для прибора изготовителем.
Источник: ГОСТ Р 52161.2.35-2008: Безопасность бытовых и аналогичных электрических приборов. Часть 2.35. Частные требования к проточным водонагревателям оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated pressure
-
6 rated frequency range
- область номинальных частот
- номинальный диапазон частот
- диапазон номинальных частот
- диапазон номинальной частоты
диапазон номинальных частот
Диапазон частот, установленный изготовителем для прибора, выраженный верхним и нижним пределами.
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]EN
rated frequency range
frequency range assigned to the appliance by the manufacturer, expressed by its lower and upper limits
[IEC 60335-1, ed. 4.0 (2001-05)]FR
plage assignée de fréquences
plage des fréquences attribuée à l'appareil par le fabricant, exprimée par ses limites inférieure et supérieure
[IEC 60335-1, ed. 4.0 (2001-05)]Тематики
EN
FR
номинальный диапазон частот
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]Тематики
- электротехника, основные понятия
EN
3.2.8 диапазон номинальной частоты (rated frequency range): Диапазон частоты, указанный на машине изготовителем, заданный нижним и верхним пределами.
Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
1.2.1.5 диапазон номинальной частоты (rated frequency range): Указанный изготовителем диапазон частоты напряжения электропитания, выражаемый нижней и верхней номинальными частотами.
Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
1.2.1.5 диапазон номинальной частоты (rated frequency range): Указанный изготовителем диапазон частоты напряжения электропитания, выражаемый нижней и верхней номинальными частотами.
Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
3.35 диапазон номинальных частот (rated frequency range): Диапазон частот, установленный для машины изготовителем и выраженный нижним и верхним пределами.
Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.2.8 диапазон номинальной частоты (rated frequency range): Диапазон частоты, указанный на машине изготовителем, заданный нижним и верхним пределами.
3.1.8 диапазон номинальных частот (rated frequency range): Диапазон частот, установленный изготовителем для прибора, выраженный верхним и нижним пределами.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
3.2.8 область номинальных частот (rated frequency range): Диапазон входных или выходных частот, указанный производителем и обозначенный нижним и верхним значениями номинальной частоты.
Источник: ГОСТ Р 55061-2012: Совместимость технических средств электромагнитная. Статические системы переключения. Часть 2. Требования и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated frequency range
-
7 rated service current
номинальный ток
Ток, указанный изготовителем на приборе
Примечание.
Если ток для прибора не указан, то номинальный ток равен:- для нагревательных приборов – току, рассчитанному по номинальной потребляемой мощности и номинальному напряжению;
- для электромеханических и комбинированных приборов – току, измеренному в период работы прибора в условиях нормальной работы при номинальном напряжении.
EN
rated current
current assigned to the appliance by the manufacturer
NOTE - If no current is assigned to the appliance, the rated current is
– for heating appliances, the current calculated from the rated power input and the rated voltage;
– for motor-operated appliances and combined appliances, the current measured when the appliance is supplied at rated voltage and operated under normal operation.
[IEC 60335-1, ed. 4.0 (2001-05)]FR
courant assigné
courant attribué à l'appareil par le fabricant
NOTE - Si aucun courant n'est attribué à l'appareil, le courant assigné est
– pour les appareils chauffants, le courant calculé à partir de la puissance assignée et de la tension assignée;
– pour les appareils à moteur et les appareils combinés, le courant mesuré lorsque l'appareil est alimenté sous la tension assignée et mis en fonctionnement dans les conditions de fonctionnement normal.
[IEC 60335-1, ed. 4.0 (2001-05)]2
номинальный ток
значение тока, являющееся исходным при установлении требований настоящего стандарта к счетчику.
[ ГОСТ 6570-96]Тематики
EN
FR
Англо-русский словарь нормативно-технической терминологии > rated service current
-
8 hot condition
рабочий режим (электровакуумного прибора)
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
3.5.3 горячий режим (hot condition): Условие для прибора, требуемое при некоторых испытаниях и получаемое путем нагрева до теплового равновесия при номинальной тепловой мощности, заявленной изготовителем.
Источник: ГОСТ Р 54788-2011: Кондиционеры абсорбционные и адсорбционные и/или тепловые насосы газовые с номинальной тепловой мощностью до 70 кВт. Часть 1. Безопасность оригинал документа
Англо-русский словарь нормативно-технической терминологии > hot condition
-
9 rated power input range
диапазон номинальных потребляемых мощностей
Диапазон мощностей, установленный изготовителем для прибора, выраженный верхним и нижним пределами.
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]EN
rated power input range
power input range assigned to the appliance by the manufacturer, expressed by its lower and upper limits
[IEC 60335-1, ed. 4.0 (2001-05)]FR
plage assignée de puissances
plage de puissances attribuée à l'appareil par le fabricant, exprimée par ses limites inférieure et supérieure
[IEC 60335-1, ed. 4.0 (2001-05)]Тематики
EN
FR
3.1.5 диапазон номинальных потребляемых мощностей (rated power input range): Диапазон мощностей, установленный изготовителем для прибора, выраженный верхним и нижним пределами.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated power input range
-
10 rated power input
номинальная потребляемая мощность
Потребляемая мощность, установленная изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]EN
rated power input
power input assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]FR
puissance assignée
puissance attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]Тематики
EN
FR
3.12 номинальная подводимая мощность (rated power input): Мощность, необходимая насосу в номинальных условиях.
Источник: ГОСТ Р 54806-2011: Насосы центробежные. Технические требования. Класс 1 оригинал документа
3.1.4 номинальная потребляемая мощность (rated power input): Потребляемая мощность, установленная изготовителем для прибора.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated power input
-
11 instrument security current
- ток, безопасный для прибора
ток, безопасный для прибора
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]Тематики
- электротехника, основные понятия
EN
Англо-русский словарь нормативно-технической терминологии > instrument security current
-
12 UN
городская сеть
городская электросеть
-
[Лугинский Я. Н. и др. Англо-русский словарь по электротехнике и электроэнергетике. 2-е издание - М.: РУССО, 1995 - 616 с.]Тематики
Синонимы
EN
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
3.11 уникальный идентификатор предмета (unique item identifier; UN): Номер, используемый для уникальной идентификации отдельного предмета учета, действительный в течение всего срока его службы.
Примечание 1 - В случае, если радиочастотная метка повторно используется для идентификации другого предмета, то ранее записанный на нее идентификатор предмета должен быть изменен.
Примечание 2 - Уникальный идентификатор Министерства обороны США (DoD Unique Identifier) и электронный код продукции (ЕРС) являются разновидностями идентификатора предмета. Например, идентификатор GS1 SSCC является идентификатором предмета (Item ID; IID) с ограниченным сроком действия, идентификатор GS1 GRAI - идентификатором предмета для присвоения возвратным активам, GS1 sGTIN - идентификатором предмета для присвоения товарной продукции.
Примечание 3 - Вместо термина «уникальный идентификатор предмета» не рекомендуется применять термин «уникальный идентификатор (UID)». То же самое относится к терминам «идентификатор микросхемы», «идентификатор радиочастотной метки» или «идентификатор объекта».
Источник: ГОСТ Р ИСО/МЭК 15963-2011: Информационные технологии. Радиочастотная идентификация для управления предметами. Уникальная идентификация радиочастотных меток оригинал документа
Англо-русский словарь нормативно-технической терминологии > UN
-
13 rated frequency
номинальная рабочая частота
—
[Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]Тематики
- электротехника, основные понятия
EN
номинальная частота
Частота, указанная изготовителем на приборе.
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]EN
rated frequency
frequency assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]FR
fréquence assignée
fréquence attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]Тематики
EN
FR
номинальная частота fном
Значение частоты, на работу при которой рассчитан трансформатор
(МЭС 421-04-03).
[ ГОСТ 30830-2002]EN
rated frequency
the frequency at which the transformer or reactor is designed to operate
[IEV number 421-04-03]FR
fréquence assignée
fréquence à laquelle le transformateur ou la bobine d'inductance sont destinés à fonctionner
[IEV number 421-04-03]Тематики
Классификация
>>>EN
DE
FR
3.2.7 номинальная частота (rated frequency): Частота, указанная изготовителем машины.
Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.6 номинальная частота (rated frequency): Частота, маркируемая на лампе.
Источник: ГОСТ Р 53881-2010: Лампы со встроенными пускорегулирующими аппаратами для общего освещения. Требования безопасности оригинал документа
1.2.1.4 номинальная частота (rated frequency): Указанная изготовителем частота электропитания.
Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
1.2.1.4 номинальная частота (rated frequency): Указанная изготовителем частота электропитания.
Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
3.15 установленная частота (rated frequency); fN:Частота, для работы на которой предназначена измерительная аппаратура.
Источник: ГОСТ Р 54127-1-2010: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
3.5 номинальная частота (rated frequency): Частота, указанная для прибора производителем.
Источник: ГОСТ Р МЭК 62301-2011: Приборы бытовые электрические. Измерение потребляемой мощности в режиме ожидания оригинал документа
3.34 номинальная частота (rated frequency): Частота, установленная для машины изготовителем.
Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.2.7 номинальная частота (rated frequency): Частота, указанная изготовителем машины.
3.4 номинальная частота (rated frequency): Частота, маркируемая на лампе.
Источник: ГОСТ Р МЭК 62560-2011: Лампы светодиодные со встроенным устройством управления для общего освещения на напряжения свыше 50 В. Требования безопасности оригинал документа
3.1.7 номинальная частота (rated frequency): Частота, указанная изготовителем на приборе.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
3.2.7 номинальная частота (rated frequency): Рабочая частота, указанная производителем.
Источник: ГОСТ Р 55061-2012: Совместимость технических средств электромагнитная. Статические системы переключения. Часть 2. Требования и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated frequency
-
14 nominal voltage
- номинальное напряжение химического источника тока
- номинальное напряжение пьезоэлектрического (электромеханического) фильтра
- номинальное напряжение аккумулятора
- номинальное напряжение
- напряжение номинальное
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
номинальное напряжение пьезоэлектрического (электромеханического) фильтра (Uном, Unom)
Значение входного напряжения, при котором измеряют параметры пьезоэлектрического (электромеханического) фильтра.
[ ГОСТ 18670-84]Тематики
EN
FR
номинальное напряжение химического источника тока
номинальное напряжение
Условное напряжение, определяемое электрохимической системой химического источника тока.
[ ГОСТ 15596-82]EN
nominal voltage
suitable approximate value of the voltage used to designate or identify a cell, a battery or an electrochemical system
[IEV number 482-03-31]FR
tension nominale, f
valeur approchée appropriée d’une tension, utilisée pour désigner ou identifier un élément, une batterie, ou un système électrochimique
[IEV number 482-03-31]Тематики
Классификация
>>>Синонимы
EN
DE
FR
- tension nominale, f
1.3.2 номинальное напряжение (nominal voltage): Номинальное напряжение герметичного никель-кадмиевого аккумулятора, равное 1,2 В.
Источник: ГОСТ Р МЭК 60622-2010: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Герметичные никель-кадмиевые призматические аккумуляторы оригинал документа
3.3.6 номинальное напряжение аккумулятора (nominal voltage): Номинальное напряжение герметичного никель-металл-гидридного аккумулятора, равное 1,2 В.
Источник: ГОСТ Р МЭК 61951-2-2007: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Портативные герметичные аккумуляторы. Часть 2. Никель-металл-гидрид оригинал документа
3.4 номинальное напряжение (nominal voltage): Подходящее приблизительное значение напряжения, используемое для идентификации напряжения аккумулятора или батареи.
Примечания
1. Номинальное напряжение литиевых аккумуляторов указано в таблице 1.
2. Номинальное напряжение батареи, состоящей из n соединенных последовательно аккумуляторов, равно номинальному напряжению отдельного аккумулятора, увеличенному в n раз.
Источник: ГОСТ Р МЭК 61960-2007: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы и аккумуляторные батареи литиевые для портативного применения оригинал документа
1.3.2 номинальное напряжение (nominal voltage): Номинальное напряжение открытого никель-кадмиевого аккумулятора с газовой рекомбинацией, равное 1,2 В.
Источник: ГОСТ Р МЭК 60623-2008: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы никель-кадмиевые открытые призматические оригинал документа
3.22 напряжение номинальное (nominal voltage): Максимально приближенное значение напряжения, принятое для удобства обозначения и идентификации аккумулятора или батареи одной электрохимической системы.
Источник: ГОСТ Р МЭК 62485-2-2011: Батареи аккумуляторные и установки батарейные. Требования безопасности. Часть 2. Стационарные батареи оригинал документа
3.2 номинальное напряжение (nominal voltage): Номинальное напряжение открытого никель-кадмиевого аккумулятора с газовой рекомбинацией, равное 1,2 В.
Источник: ГОСТ Р МЭК 62259-2007: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы никель-кадмиевые призматические с газовой рекомбинацией оригинал документа
3.15 номинальное напряжение (nominal voltage): Соответствующее приблизительное значение напряжения, которое используют при проектировании или идентификации элемента, батареи или электрохимической системы.
[IEV 482-03-31:2004]
Источник: ГОСТ Р МЭК 60086-4-2009: Батареи первичные. Часть 4. Безопасность литиевых батарей оригинал документа
3.10 номинальное напряжение (nominal voltage): Соответствующее приблизительное значение напряжения, которое используют для идентификации первичной батареи.
Источник: ГОСТ Р МЭК 60086-5-2009: Батареи первичные. Часть 5. Безопасность батарей с водным электролитом оригинал документа
3.18 номинальное напряжение (nominal voltage) Un: Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
Источник: ГОСТ Р 51317.4.30-2008: Электрическая энергия. Совместимость технических средств электромагнитная. Методы измерений показателей качества электрической энергии оригинал документа
3.17 номинальное напряжение (nominal voltage): Номинальное значение напряжения, которое определяет тип источника питания.
Источник: ГОСТ Р 55266-2012: Совместимость технических средств электромагнитная. Оборудование сетей связи. Требования и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > nominal voltage
-
15 instrument opening
English-Russian dictionary on nuclear energy > instrument opening
-
16 rated voltage range
- область регламентированных напряжений
- диапазон номинальных напряжений
- диапазон номинального напряжения
диапазон номинальных напряжений
Диапазон напряжений, установленный изготовителем для прибора, выраженный верхним и нижним пределами.
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]EN
rated voltage range
voltage range assigned to the appliance by the manufacturer, expressed by its lower and upper limits
[IEC 60335-1, ed. 4.0 (2001-05)]FR
plage assignée de tensions
plage des tensions attribuée à l'appareil par le fabricant, exprimée par ses limites inférieure et supérieure
[IEC 60335-1, ed. 4.0 (2001-05)]Тематики
EN
FR
3.2.2 диапазон номинального напряжения (rated voltage range): Диапазон напряжений, указанный изготовителем для машины и заданный нижним и верхним пределами.
Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
1.2.1.2 диапазон номинального напряжения (rated voltage range): Указанный изготовителем диапазон напряжения источника сетевого электропитания, выражаемый нижним и верхним значениями номинального напряжения.
Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
1.2.1.2 диапазон номинального напряжения (rated voltage range): Указанный изготовителем диапазон напряжения источника сетевого электропитания, выражаемый нижним и верхним значениями номинального напряжения.
Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
3.41 диапазон номинальных напряжений (rated voltage range): Диапазон напряжений, установленный для машины изготовителем и выраженный нижним и верхним пределами.
Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.2.2 диапазон номинального напряжения (rated voltage range): Диапазон напряжений, указанный изготовителем для машины и заданный нижним и верхним пределами.
3.2.2. диапазон номинальных напряжений (rated voltage range):
Интервал между максимальным и минимальным напряжениями, предусмотренными изготовителем и указанными на оборудовании.
Источник: ГОСТ Р МЭК 60519-1-2005: Безопасность электротермического оборудования. Часть 1. Общие требования оригинал документа
3.2.5 область регламентированных напряжений (rated voltage range): Диапазон входного или выходного напряжения, заданный производителем и обозначенный нижним и верхним значениями номинального напряжения.
Источник: ГОСТ Р 55061-2012: Совместимость технических средств электромагнитная. Статические системы переключения. Часть 2. Требования и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated voltage range
-
17 tap opening
-
18 rated power
- расчетная мощность
- номинальная мощность электроагрегата (электростанции)
- номинальная мощность Sном
- номинальная мощность
номинальная мощность Sном
Полная мощность, определяющая вместе с номинальным напряжением номинальный ток обмотки.
Примечания
1 В двухобмоточном трансформаторе обе обмотки имеют одинаковую номинальную мощность, равную номинальной мощности трансформатора.
2 Для многообмоточного трансформатора половина суммы значений номинальных мощностей всех обмоток (раздельных обмоток без автотрансформаторного соединения) дает приблизительную оценку габаритных размеров многообмоточного трансформатора по сравнению с двухобмоточным трансформатором.
[ ГОСТ 30830-2002]EN
rated power
a conventional value of apparent power, establishing a basis for the design of a transformer, a shunt reactor or an arc-suppression coil, the manufacturer's guarantees and the tests, determining a value of the rated current that may be carried with rated voltage applied, under specified conditions
NOTE – Both windings of a two-winding transformer have the same rated power, which by definition is the rated power of the transformer. For multi-winding transformers the rated power for each of the windings may diffe
[IEV number 421-04-04]FR
puissance assignée
valeur conventionnelle de la puissance apparente, destinée à servir de base à la conception du transformateur, de la bobine d'inductance shunt ou de la bobine d'extinction d'arc, aux garanties du constructeur et aux essais, en déterminant une valeur de courant assigné admissible lorsque la tension assignée est appliquée, dans des conditions spécifiées
NOTE – Les deux enroulements d'un transformateur à deux enroulements ont la même puissance assignée, qui est par définition la puissance assignée du transformateur. Dans le cas de transformateurs à plus de deux enroulements, la puissance assignée de chacun des enroulements peut être différente
[IEV number 421-04-04]Тематики
Классификация
>>>EN
DE
номинальная мощность электроагрегата (электростанции)
номинальная мощность
Мощность, развиваемая электроагрегатом (электростанцией) без ограничения времени работы при номинальных значениях напряжения, тока, частоты вращения, частоты переменного тока, коэффициента мощности и при номинальных условиях эксплуатации, с учетом возможности развития максимальной мощности.
[ ГОСТ 20375-83]Тематики
Синонимы
EN
DE
расчетная мощность
—
[Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]Тематики
EN
55. Номинальная мощность электроагрегата (электростанции)
Номинальная мощность
D. Nennleistung
E. Rated power
Мощность, развиваемая электроагрегатом (электростанцией) без ограничения времени работы при номинальных значениях напряжения, тока, частоты вращения, частоты переменного тока, коэффициента мощности и при номинальных условиях эксплуатации, с учетом возможности развития максимальной мощности
Источник: ГОСТ 20375-83: Электроагрегаты и передвижные электростанции с двигателями внутреннего сгорания. Термины и определения оригинал документа
3.3 номинальная мощность (rated power): Потребляемая мощность, указанная для прибора производителем.
Источник: ГОСТ Р МЭК 62301-2011: Приборы бытовые электрические. Измерение потребляемой мощности в режиме ожидания оригинал документа
3.12 номинальная мощность (rated power): Величина мощности, объявленная производителем и соответствующая указанным режимам эксплуатации устройства или оборудования.
Примечание - Номинальная мощность - величина максимальной непрерывной электрической мощности, выдаваемой в режиме нормальной эксплуатации и при нормальных внешних условиях, которая была задана в процессе проектирования ВЭУ.
Источник: ГОСТ Р 54418.12.1-2011: Возобновляемая энергетика. Ветроэнергетика. Установки ветроэнергетические. Часть 12-1. Измерение мощности, вырабатываемой ветроэлектрическими установками оригинал документа
3.14 номинальная мощность (rated power), QH (QN): Реактивная мощность реактора, заданная для работы при номинальных напряжении и частоте.
Источник: ГОСТ Р 54801-2011: Трансформаторы тяговые и реакторы железнодорожного подвижного состава. Основные параметры и методы испытаний оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated power
-
19 design voltage
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
3.7 номинальное напряжение (design voltage): Объявленное изготовителем напряжение, к которому относятся все характеристики устройства управления лампами и которое должно быть не менее 85 % наибольшего значения диапазона нормируемого напряжения.
Источник: ГОСТ Р МЭК 61347-1-2011: Устройства управления лампами. Часть 1. Общие требования и требования безопасности оригинал документа
Англо-русский словарь нормативно-технической терминологии > design voltage
-
20 rated water pressure
3.117 номинальное давление воды (rated water pressure): Давление воды для прибора, установленное изготовителем.
Источник: ГОСТ Р 52161.2.6-2006: Безопасность бытовых и аналогичных электрических приборов. Часть 2.6. Частные требования для стационарных кухонных плит, конфорочных панелей, духовых шкафов и аналогичных приборов оригинал документа
Англо-русский словарь нормативно-технической терминологии > rated water pressure
См. также в других словарях:
ток, безопасный для прибора — — [Я.Н.Лугинский, М.С.Фези Жилинская, Ю.С.Кабиров. Англо русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.] Тематики электротехника, основные понятия EN instrument security current … Справочник технического переводчика
ГОСТ Р 52161.2.6-2006: Безопасность бытовых и аналогичных электрических приборов. Часть 2.6. Частные требования для стационарных кухонных плит, конфорочных панелей, духовых шкафов и аналогичных приборов — Терминология ГОСТ Р 52161.2.6 2006: Безопасность бытовых и аналогичных электрических приборов. Часть 2.6. Частные требования для стационарных кухонных плит, конфорочных панелей, духовых шкафов и аналогичных приборов оригинал документа: 22.105… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р 52161.2.21-2006: Безопасность бытовых и аналогичных электрических приборов. Часть 2.21. Частные требования для аккумуляционных водонагревателей — Терминология ГОСТ Р 52161.2.21 2006: Безопасность бытовых и аналогичных электрических приборов. Часть 2.21. Частные требования для аккумуляционных водонагревателей оригинал документа: 3.101 аккумуляционный водонагреватель (storage water heater):… … Словарь-справочник терминов нормативно-технической документации
Диапазон номинальных частот прибора — Диапазон номинальных частот диапазон частот, установленный изготовителем для прибора, выраженный верхним и нижним пределами... Источник: ГОСТ 27570.0 87 (МЭК 335 1 76). Безопасность бытовых и аналогичных электрических приборов. Общие требования и … Официальная терминология
Номинальная продолжительность работы прибора — Номинальная продолжительность работы продолжительность работы, установленная изготовителем для прибора... Источник: ГОСТ 27570.0 87 (МЭК 335 1 76). Безопасность бытовых и аналогичных электрических приборов. Общие требования и методы испытаний… … Официальная терминология
ГОСТ Р 53635-2009: Газовые воздухонагреватели с принудительной конвекцией для отопления (обогрева) помещений теплопроизводительностью до 100 кВт. Общие технические требования и методы испытаний — Терминология ГОСТ Р 53635 2009: Газовые воздухонагреватели с принудительной конвекцией для отопления (обогрева) помещений теплопроизводительностью до 100 кВт. Общие технические требования и методы испытаний оригинал документа: 3.2.2… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р 52161.2.24-2007: Безопасность бытовых и аналогичных электрических приборов. Часть 2.24. Частные требования к холодильным приборам, мороженицам и устройствам для производства льда — Терминология ГОСТ Р 52161.2.24 2007: Безопасность бытовых и аналогичных электрических приборов. Часть 2.24. Частные требования к холодильным приборам, мороженицам и устройствам для производства льда оригинал документа: 3.109 воспламеняющийся… … Словарь-справочник терминов нормативно-технической документации
ГОСТ 18065-91: Станки зубофрезерные горизонтальные для цилиндрических колес. Основные параметры и размеры. Нормы точности — Терминология ГОСТ 18065 91: Станки зубофрезерные горизонтальные для цилиндрических колес. Основные параметры и размеры. Нормы точности оригинал документа: 2.2.7. Осевое биение шпинделя фрезы Черт. 12 Таблица 8 Наибольший диаметр обрабатываемого… … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р МЭК 61676-2006: Медицинское электрическое оборудование. Дозиметрические приборы, используемые для неинвазивного измерения напряжения на рентгеновской трубке в диагностической радиологии — Терминология ГОСТ Р МЭК 61676 2006: Медицинское электрическое оборудование. Дозиметрические приборы, используемые для неинвазивного измерения напряжения на рентгеновской трубке в диагностической радиологии оригинал документа: 3.24 ВЕЛИЧИНА… … Словарь-справочник терминов нормативно-технической документации
ГОСТ 659-89: Станки зубофрезерные вертикальные для цилиндрических колес. Основные параметры и размеры. Нормы точности — Терминология ГОСТ 659 89: Станки зубофрезерные вертикальные для цилиндрических колес. Основные параметры и размеры. Нормы точности оригинал документа: 2.2.7. Осевое биение инструментального шпинделя Черт. 9 Черт. 10 Таблица 8 … Словарь-справочник терминов нормативно-технической документации
ГОСТ Р 54671-2011: Кондиционеры, агрегатированные охладители жидкости и тепловые насосы с компрессорами с электроприводом для обогрева и охлаждения помещений. Термины и определения — Терминология ГОСТ Р 54671 2011: Кондиционеры, агрегатированные охладители жидкости и тепловые насосы с компрессорами с электроприводом для обогрева и охлаждения помещений. Термины и определения оригинал документа: 2.6 агрегатированное устройство … Словарь-справочник терминов нормативно-технической документации